Certificate Of Quality
Sample of Neutral Ethyl Alcohol – 06.04.2005 SGS Brasil OG&C-603.239/05
TEST |
METHOD |
LIMITS |
RESULT |
Alcohol Content Gl at 20C |
ASTM D 4052 |
Min.96,2 |
96,6 |
Aldehydes (as acetaldehydes),mg/100ml |
GLC |
Max.0,5 |
Less than 0,5 |
Acidity (as Acetic Acid), mg/100ml |
ASTM D 1613 |
Max.0,5 |
0,3 |
Benzene, ppm |
UV |
Absent |
Absent |
Chlorides,ppm * |
Turbidimetric |
Absent |
Absent |
Sulphur,ppm * |
ASTM D 3120 |
Absent |
Absent |
Crotonaldehyde,ppm ** |
GLC |
Negative |
Negative |
Cyclohexane,mg/100ml |
GLC |
Negative |
Negative |
Hydrocarbons |
ASTM D 1722 |
Negative |
Negative |
Dry Extracts,mg/100ml |
ASTM D 1353 |
Max.1,5 |
0,3 |
Esters(Ethyl Acetate),mg/100ml |
GLC |
Max.1,0 |
Less than 0,5 |
Methanol,mg/100ml |
GLC |
Max.1,0 |
Less than 0,5 |
Isopropanol,mg/100ml |
GLC |
Max.1,0 |
Less than 0,5 |
Permanganate time tests at 20C |
ASTM D 1653 |
Min.10 |
26:00 |
Total Higher Alcohols,mg/100ml |
GLC |
Max.1,0 |
Less than 0,5 |
Alkalinity |
ASTM D 1613 |
Negative |
Negative |
Aspect |
Visual |
Clear and exempt from material in suspension |
Clear and exempt from material in suspension |
Sulphate, ppm |
Spectrophotometer |
Absent |
Absent |
Absorption UV (1cm-water) |
- |
- |
- |
Absorption UV (cell form) at 220nm |
UV |
Max.0,20 |
0,19 |
Absorption UV (cell form) at 230nm |
UV |
Max.0,10 |
0,09 |
Absorption UV (cell form) at 240nm |
UV |
Max.0,05 |
0,03 |
Absorption UV (cell form) at 270nm |
UV |
Max.0,02 |
0,001 |
* Limits of detection ** Limits of detection 0,5 ppm SLCMP